LMC magnetically encoded contactless safety switch

1681349668169125.pngimage.png

Compact non-contact magnetic coded switch, easy to install in narrow frame structure.

?12mm wide, can sense the tolerance of height deviation.

?Meet the requirements of Class 3 standards.

?When combined with dual-channel safety relay, coded contactless switch can be used to provide protection up to Class 4 and PLe to ISO13849.


395181ccb7a771e30162f6415dc922a.png

Ordering information

1588126326899852.png

Switch model

Contact configuration

Catheter opening/connector

type

LMC3-48

2NC

3M direct outlet

Coding universal type

LMC4-48

2NC

3M direct outlet

Coded unique type

Description:

Configuring LHS security module can construct security system above PLd.


395181ccb7a771e30162f6415dc922a.png

technical parameter

security level/phase

Safety grade standard

ISO 13849-1, IEC/EN 60947-5-3

Safety classification

Class 3 switches conforming to ISO 13849-1; Dual-channel interlock is suitable for Class 3 or Class 4 systems.

output

Safe output

2個(gè)N.C.REEDS

Outlet mode

Direct outlet

technical parameter

working distance

Turn on. min: 8 mm; Disconnect. max: 17 mm

Typical tolerance

See alignment schematic.

Output current (maximum)

200mA

Response time

5ms

the protection grades

IP67(IP69K can be customized)

Operating frequency

lHz

Working temperature

-10~+55℃

relative humidity

5%~95%

material

UL certified thermoplastics


395181ccb7a771e30162f6415dc922a.png

Shape and installation dimensions

Horizontal alignment

The deviation is within ±2mm in the X direction.

立宏電磁性感應(yīng)安全開關(guān)6.png

The deviation is between-4 mm and-2 mm and between 2 mm and 4 mm in the X direction.

Z-direction induction distance > >17m

Vertical alignment

The deviation is within ±2mm in the X direction.

Y direction induction distance 0~8m

Y direction induction distance > >17mm


395181ccb7a771e30162f6415dc922a.png

Shape and installation dimensions

62c61c9382e4223bb9b96a949eddf23.png222222222222222222.png66666666666.png


395181ccb7a771e30162f6415dc922a.png

Head installation direction

7777777777777777777777777.pngserial numberSignal definitioncolour
1Output A1
black
2Output A2white
3Output B1ash
4Output B2green

Note: A1/A2 is a set of switch outputs.

B1/B2 is a set of switch outputs.

For constructing safety loop level, please use safety controller.


395181ccb7a771e30162f6415dc922a.png

PLD safety circuit wiring case

1684284692376370.png

1684285950663726.png


Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh