As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

(1) Redundancy

(2) Difference

(3) Self-detection


   How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.

SC-4 security expansion module

841056c.png

· Is a safety relay output expansion module.

· Receive the on-site safety switch signal, and expand it into 4 NO (normally open) safety output contacts and 2 NC (normally closed) auxiliary output contacts. 
· Two auxiliary contacts can be used for output status indication and fault feedback respectively.

Product selection     0523ce09f27183840accf49d6c9b5a4.png

product name

model

Safety input

Safe output

order number

SC-4

24V DC

Safety switch, contact switch

4NO+2NC

LHS
explain

Safety switch, contact switch


safety performance

·Performance level (PL): PLE

·Safety category (cat.): cat.4.

·Task time (TM): 20 years.

·Diagnostic coverage (DC/DC AVG): 99%

·Safety integrity level (SIL): SIL3

·Hardware fault margin (HFT): 1

·Safety Failure Score (SFF): 99%

·PFHD: 1.78e-9/h

·Stop category: 0           

Comply with the standard EN ISO13849

Comply with the standard EN ISO13849

Comply with the standard EN ISO13849

Comply with the standard EN ISO13849

Comply with standards IEC61508, IEC62061.

Comply with standards IEC61508, IEC62061.

Comply with standards IEC61508, IEC62061.

Comply with standards IEC61508, IEC62061.

Comply with standard EN 60204-1.


Main technical parameters

Power supply characteristics

·Power supply voltage: 24VDC

·Voltage range: -15%~+10%

·Current loss: ≤70mA(24VDC)

Input characteristics

·Input current: ≤70mA(24VDC)

·Conductor resistance: ≤15Ω

·Input equipment: safety switch, contact switch.

output characteristic

·Number of contacts: 4NO+2NC

       Safety outputs: 13, 14, 23, 24, 33, 34, 43, 44.

       Auxiliary outputs: 11, 12 (status)

       Y1, Y2 (feedback)

·Contact material: AgSnO2+0.2 μm Au.

·Contact type: forced guidance

·Contact fuse protection: 10A gL/gG, NEOZED (normally open contact)

       6A gL/gG, NEOZED (normally closed contact)

·Switching capacity (en 60947-5-1): AC-15, 5a/230v; DC-13, 5A/24V

·Mechanical life: more than 107 times

Time characteristic

·Suction buffer time: ≤30ms

·Release buffer time: ≤20ms

·Recovery time: ≤1000ms

·Short interruption of power supply: 20ms


Environmental characteristic parameters

·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

·Vibration frequency: 10Hz~55Hz

·Vibration amplitude: 0.35mm

·Operating temperature: -20℃~+60℃

·Storage temperature: -40℃~+85℃

·Relative humidity: 10%~90%

·Electrical clearance and creepage distance: in accordance with EN60947-1.

·Overvoltage grade: Ⅲ

·Pollution level: 2

·Altitude: ≤2000m

·Rated isolation voltage: 250VAC.

·Rated impulse voltage: 6000V(1.2/50us)

·Insulation strength: 1500VAC for 1min.

841056c.png


Functional application parameters

functional block diagram

Typical application

圖片2.png

典型應(yīng)用圖.png


Overall dimensions (depth× height× width):

Overall dimensions (depth× height× width):114.5mm×99.0mm×22.5mm

Net weight of product200g

外形尺寸圖.png


Wiring diagram

Power supply/input loop

Switch input

電路圖1.png

Output loop

電路圖2.png

feedback loop

電路圖3.png


Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh