中文字幕在线日亚州9-色妞www精品免费视频-国产日韩精品欧美一区喷水-久久精品国产一区二区电影

Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
Position首頁 > Home > Safety products > Safety Relays 安全控制器 > Strong conduction safety relay
G6SA strong conductance relay


G6SA-4A2B safety relay (relay with forced guide contact)
圖片11.png

·Four groups normally open+two groups normally closed

·Force-guided contact structure (conforming to IEC 61810-3 standard)

·Strong load capacity: 6A contact switching ability

·Low input power consumption: 500mW

·Strong insulation capability: input-output bears 10kV surge voltage.

·UL insulation grade: f insulation grade is available for selection.


Product selection

product name

model

Contact form

brand

safety relay

G6SA-4A2B

4NO+2NC

LHS

explain



Contact parameters

Contact form

4NO+2NC

Structure classification (according to IEC 61810-3)

Class a compulsory guidance

Contact resistance (1)

100mΩ (1A 6VDC)

Contact material

AgSnO2

Contact load (resistive)

6A 250VAC / 30VDC

Maximum switching voltage

400VAC / 30VDC

Maximum switching current

6A

Maximum switching power

1500VA /180W

Electrical durability

1×105 times (1NO:6A 30VDC, resistive load, room temperature, 1s on and 9s off)

1×105 times (1NO:6A 250VAC, resistive load, room temperature, 1s on and 9s off)

Mechanical durability

1×107次


Coil parameters

Rated coil power

約500mW


Coil specification sheet

Rated voltage VDC

Operating voltage VDC(1)

Release voltage VDC(1)

Maximum voltage (2)VDC

Coil resistance ω

6

≤4.5

≥0.6

6.6

72×(1±10%)

9

≤6.8

≥0.9

9.9

162×(1±10%)

12

≤9.0

≥1.2

13.2

288×(1±10%)

18

≤13.5

≥1.8

21.78

648×(1±10%)

24

≤18.0

≥2.4

26.4

1152×(1±10%)

36(3)

≤27.0

≥3.6

39.6

2592×(1±10%)

48(3)

≤36.0

≥4.8

52.8

4608×(1±10%)

Remarks:

(1) The above values are all initial values;

(2) The maximum voltage refers to the maximum voltage that the relay coil can bear in a short time;

(3) For products with rated voltage ≥36V, in order to protect the coil from damage, it must be inhibited in testing and application.

Measures to generate over-voltage in the coil (such as connecting diodes in parallel with the coil).


performance parameter

insulance

1000MΩ (500VDC)

Dielectric withstand voltage

Between coil and contact

4000VAC 1min

Disconnect contact

1500VAC 1 min

Contact group

2500VAC 1 min (11-12/13-14)

4000VAC 1 min (others)

surge voltage

Coils and contacts

10kV (1.2/50μs)

Contact group

5kV (1.2/50μs)

Action time (at rated voltage)

≤20ms

Release time (at rated voltage)

≤20ms

Coil temperature rise (at rated voltage)

≤70K(The coil driving voltage is 1.1 times Un, the contact current is rated current, and the ambient temperature is 85℃)

vibrate

NO/NC: 10Hz ~ 55Hz 1.5mm double-amplitude

NO: 55Hz ~ 200Hz, 98m/s2

NC: 55Hz ~ 200Hz, 49m/s2

lash

stability

100m/s2

intensity

980m/s2

creepage distance

Between coil and contact

8mm

Contact group

5.5mm

air interstice

Between coil and contact

8mm

Contact group

5.5mm

humidity

5%~ 85% RH

temperature range

-40℃~85℃

Lead-out form

Printed board type

weight

About 23g

package

Flux-proof type

Remarks: (1) UL insulation grade: F and B; (2) The above values are all initial values.


Outline drawing, wiring diagram and mounting hole size

outline dimension

hookup

 外形尺寸圖.png


接線圖、安裝孔尺寸.png 

Remarks:

(1) The dimension tolerance is not indicated for some external dimensions of the product. When the external dimension is ≤1mm, the tolerance is ±0.2mm;; When the outline ruler

When the inch is between (1 ~ 5)mm, the tolerance is ±0.3mm;; When the overall dimension is greater than 5 mm, the tolerance is ±0.4mm;;

(2) The dimension tolerance not indicated in the dimension of the mounting hole is 0.1 mm..


Performance curve

9.png

Remarks:

(1) Test conditions: 1NO terminal, resistive load, 250VAC, room temperature, 1s on and 9s off.

(2) The above are the typical values of the test.


Performance curve

10.png

Remarks:

According to IEC61810-1, Appendix B, Table B.3, test, at room temperature, 1NO, 1s on and 9s off.


Relay matching socket
G4SA底座.png

·The withstand voltage between the coil and the contact is 2500VAC, and the insulation resistance is 1000 mω.

Can be installed by screws or guide rails.

Protect the coil with diode to suppress reverse overvoltage.

With finger protection cover

Keep and take out the self-contained relay.



performance parameter

Socket type

rated voltage

rated current

Applicable voltage of relay coil

ambient temperature

twist moment*

Maximum conductor section size was

Bolu conductor length

weight

remarks

A6-6Z-C2-D24

250VAC

6A

(6~24)VDC

-25℃~55℃

1.0N·m

2×1.5

7mm

約63g

With indicator light


Outline drawing, wiring diagram, mounting hole size and circuit diagram

Overall dimensions: Top view unit: mm

Wiring Diagram and Installation Hole Size: Top View Unit: mm

外形尺寸圖.png11.png

電路圖

指示燈.png


Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh